HydraMotion Linear Actuator -
Mounting The HydraMotion linear actuator has a trunion mount consisting of two opposed threaded holes with a spot-face diameter 0.625. The trunion bolts must be of shoulder type where the shoulder is supported by the spot-face. It is most important that no side loads are applied to the rod of the actuator. Align the rod accurately and make sure that the orientation of the mounting axis is parallel to each other. Do not try bolts without shoulder and do not use more thread engagement than 0.375". |